In brief

  • NSW mines notified 183 fires on mobile plant in 2025 to 2026, four more than the year before, according to the NSW Resources Regulator.
  • Exhaust systems were the most common heat source and hydraulic oil the most common fuel. Hoses were the most common failed component.
  • Many fires start shortly after servicing, in workshops, wash bays, refuelling areas and park-up lines where nobody is watching the machine.
  • Flagman fire and smoke detection AI adds an earlier visual alert and video evidence in those fixed areas. It supports, and never replaces, fire suppression, maintenance quality and engineering controls.

A haul truck leaves the workshop after a turbocharger change. Forty minutes later, oil from a hose disturbed during the job finds a hot exhaust. The operator sees smoke, stops and reaches for the extinguisher.

That scenario is illustrative, but it matches the pattern the NSW Resources Regulator has reported for years: fires on mobile plant are common, they often trace back to maintenance, and the Regulator now says every one of them is avoidable and preventable.

The problem: fires on mobile plant at NSW mines

The Resources Regulator’s Fires on mobile plant 2025 to 2026 report, published in November 2026, records 183 notified fires in the year to 30 June 2026, up from 179 in 2024 to 2025. Surface coal accounted for 132 of them (72%), with underground metals next on 26.

The causes are familiar to any maintenance superintendent:

  • The exhaust system was the heat source in 31% of incidents with a completed report.
  • Hydraulic oil was the fuel in 27%, and exhaust plus hydraulic oil was the most common combination (22 incidents).
  • Hoses were the most common failed component (25 incidents), followed by hydraulic system components (23) and other electrical components (21). Hose failure from wear and tear was the most frequent failure and cause pairing.
  • A hand-held extinguisher was used in 64 incidents (36%). An automatically deployed fire protection system was used in 12.

Enforcement is rising. Notices issued after these fires increased from 2 in 2024 to 2025 to 10 in 2025 to 2026, including three prohibition notices. The Regulator states it has a “zero-tolerance approach” where operators have not taken appropriate steps to manage the risk.

Servicing is a known trigger. In Safety Bulletin SB21-11, the Regulator reported 18 fires at open cut coal mines over six months in 2021. Nine happened within the first shift after the plant returned to service, and ten came from workmanship errors that a supervisor’s inspection or a short workshop commissioning would likely have caught: loose diesel fittings, missing fuel line clamps, oil-soaked lagging and painted exhaust parts giving off vapour at start-up.

The requirement: what NSW law and the Regulator expect

In NSW, mines operate under the Work Health and Safety (Mines and Petroleum Sites) Act 2013 and Regulation 2022. Section 4 of the Regulation defines a principal hazard, and section 28 sets out what an operator must consider in a principal hazard management plan. The Resources Regulator treats fire and explosion on mobile plant as a principal hazard, with “uncontrolled fire or explosion mobile plant” listed as a material unwanted event.

All fires on mobile plant are notifiable to the Regulator, with an ancillary report covering the heat and fuel source, how the fire was put out, the root cause and the actions taken to prevent a repeat. The Regulator’s 2024 to 2025 report also told operators to ensure “stringent monitoring and quality control of maintenance and repair activities”.

Why existing controls leave a gap

Most sites already have fire suppression, engine temperature and pressure monitoring, hose sheathing and exhaust lagging. These controls come first. The gap is in the places and moments where they are least effective:

  • The first hours after return to service. A fault introduced during the job may not show until the machine is back at work.
  • Unattended areas. Park-up lines, wash bays and refuelling areas often hold hot plant with nobody nearby.
  • Workshops at night or between shifts. Hot work, solvents, oily rags and hot components share the same bays.
  • Weak evidence. When a small fire is put out quickly, the ancillary report often relies on memory.

The solution: how Flagman fire and smoke detection AI adds an earlier layer

Flagman is an AI vision system that processes video on an edge device on site, with no cloud or internet connection needed. It works with ONVIF IP cameras, so many mines can start with cameras already covering their workshops and fuel bays. The Flagman Neo edge unit is rated IP69K, fanless, and specified for minus 20 to plus 80 degrees Celsius, which suits dusty and wash-down areas.

  • Detection zones where fires start. You draw zones over workshop bays, return-to-service test areas, wash bays, refuelling and lube bays, and park-up lines. When the system sees smoke or flame in a zone, it raises an alert as it happens.
  • Alerts that reach people. Audio alarms, beacons or recorded voice messages at the bay, plus a notification on the central dashboard for the control room or shift supervisor.
  • Integration with site systems. Relay outputs and PLC integration over Modbus or PROFINET can trigger warning beacons or notify the emergency response team, where your systems are designed to accept that signal.
  • Evidence for the ancillary report. Every event is logged with time-stamped video, showing where smoke first appeared.

For the response that follows, read our guide to emergency mustering and people counting on mine sites, and see how the same detection approach applies in warehouse fire and smoke detection.

Predictive maintenance: fixing the plant condition behind the fire

The Regulator’s data points straight at plant condition. Worn hoses, failed hydraulic components, loose fittings and damaged lagging are maintenance problems before they are fire problems. Predictive and condition-based maintenance, such as oil analysis, thermal imaging of exhaust and turbo areas, and tracking repeat defects by machine, finds those faults before they become a fuel source next to a heat source.

The value grows when maintenance data sits beside safety data. Sharktech Global builds Business Intelligence dashboards that bring maintenance, downtime and safety data together, including Flagman events. A mine can then see whether smoke alerts cluster around one fleet, one component type or the first shift after a particular kind of service, and act on the equipment and the workshop process rather than the alarm.

Limitations: what Flagman cannot do

  • Flagman is not a certified fire detection or fire suppression system. It does not replace on-board suppression, engine monitoring, hose sheathing, lagging or the critical controls in your principal hazard management plan.
  • It sees only what a camera sees. A fire starting inside an engine compartment will not be detected until smoke or flame is visible to the camera.
  • Fixed cameras cover fixed areas. Flagman in this setup does not watch plant travelling in the pit or on haul roads.
  • Flagman has no hazardous area (IECEx or ANZEx) certification. It must not be used in underground coal mines or explosive atmospheres.
  • Dust, steam from wash bays, exhaust and sun glare can cause false alerts. Zones need tuning during a trial so operators trust every alert.
  • Workplace cameras trigger NSW workplace surveillance obligations, including 14 days’ written notice, visible cameras and signage. Consult workers and health and safety representatives first.

A practical plan for reducing mobile plant fires

  1. Pull your last two years of fire notifications and near misses. Map where each fire was found and how long after servicing.
  2. Review return-to-service worksheets against SB21-11, including torque marking and a follow-up spanner check one to two hours after return to service.
  3. Set hose and lagging replacement criteria by condition and age, and track repeat defects by machine.
  4. Survey camera coverage of workshops, wash bays, refuelling bays and park-up lines. Identify the areas that are hot and unattended.
  5. Run a Flagman trial in two or three of those areas, tune the zones, and agree who responds to each alert.
  6. Link alerts and video logs into your incident process and ancillary reporting, and review the data monthly with maintenance.

The outcome you can measure

A well-run deployment should give you an alert at the point of risk in areas that were previously unwatched, a time-stamped video record for every smoke or flame event, a baseline of fire and smoke events by area and by time since service, and maintenance and safety data in one view.

Flagman in Australia: local delivery by Sharktech Global

Sharktech Global, based in Liverpool, New South Wales, is the exclusive Australian and New Zealand delivery partner for Perleybrook Labs, which designs and manufactures Flagman. Sharktech Global assesses sites, installs and integrates Flagman with existing cameras, alarms and plant controls, and provides local support during business hours. Learn more about Sharktech Global’s services for mining and resources operations.

Key takeaways

  • NSW mines notified 183 fires on mobile plant in 2025 to 2026, and Regulator notices rose fivefold.
  • Flagman adds earlier smoke and flame alerts and video evidence in workshops, wash bays, fuel bays and park-up lines. It strengthens, and never replaces, on-board fire controls and maintenance discipline.

Next step

Request a Flagman safety assessment or call Sharktech Global on 0468 017 373. The assessment reviews your workshops, refuelling and park-up areas and camera coverage, and shows where earlier fire and smoke alerts would add the most protection.

Sources: NSW Resources Regulator, Fires on mobile plant 2025 to 2026 (November 2026); Fires on mobile plant 2024 to 2025; Safety Bulletin SB21-11, Fires occur after servicing mobile plant; Fact sheet, Principal hazard: fire and explosion, mobile plant; Fires on mobile plant safety; Guide, Preparing a principal hazard management plan. This article is general information, not legal advice. Check your obligations with the regulator or a qualified adviser.